亚洲国产欧洲一区二区_亚洲欧美香蕉在线日韩精选_日韩欧美日韩国产在线播放_亚洲av高清手机在线_亚洲精品无播放器播放_freevideos在线等最新內容_亚洲av无码成人h动漫_小小视频在线观看免费资源_少妇人妻系列无码专视频区_妇女满足农民工特级毛片

Wechat QR code

監(jiān)護(hù)儀廠家,腦電圖機(jī),美倫,美倫醫(yī)療電子有限公司

TEL:400-654-1200

Meilun Medical

Stock code 871562

Phone:

400-654-1200

What do you want to know?

監(jiān)護(hù)儀廠家,腦電圖機(jī),美倫,美倫醫(yī)療電子有限公司
Current position: Homepage >> News >> Company news

Maintenance of monitor

The number of clicks:
Release date: 2015-12-31 09:03:53
Source: Henan Meilun Medical Electronics Co., Ltd.
share it

Maintenance: due to the characteristics of sensor sensor itself and the detected location of the patients often in practice, so it is easy to damage the parts, is an important part of the more expensive. In order to extend their period of use, reduce the cost of treatment, we should do more for their maintenance work. Often communicate with the medical staff, guide them to correct operation and maintenance of monitor and sensor. Not fold, pull transmission wire sensor; probe cannot fall, touch sensor probe, such as oxygen saturation temperature, invasive blood pressure probe. For the non invasive blood pressure cuff, in the absence of strapping on the patient host at this time cannot be measured, so as to avoid damage to the inflation of the airbag. When the monitor to care for a long time without the need for monitoring the blood oxygen saturation, to turn off this feature through adjusting the configuration of the system, if the machine has this setting or unplug the oxygen saturation of blood is connected to the host interface monitors are generally through the interface to connect each sensor, so as to prolong the service life of this kind of sensor.

Sensor probe easily stained with sweat, blood and other dirt, to avoid corrosion probe and measurement to regularly according to the user's manual provides a method of cleaning the probe. System maintenance: the monitor system is set properly, or even wrong, often for health care workers in trouble. For example: a wave shape, without heart rate; not measuring blood pressure in hypertensive patients; the parameters of normal, but the alarm time and so on, these are likely to be caused by the wrong system settings. Therefore, should always check the maintenance system to ensure the reliability of monitoring, optimality, i.e. the optimal configuration. Although the monitor various, specific methods of system settings of each are not identical, but most of them have the following aspects: patient information in the information should pay attention to is the types of patients choose to correct. Generally divided into neonatal, adult and children, they were measured using different schemes, if the wrong will affect the measurement accuracy, and even can not be measured. For example, noninvasive blood pressure is likely to detect and display the error.


Maintenance of monitor