The use and maintenance of ecg monitor

The number of clicks:
Release date: 2016-08-11 00:00:00
Source: Henan Meilun Medical Electronics Co., Ltd.
share it

With the improvement of medical technology, multi-function ecg monitor manufacturer has been widely used in clinical.Ecg monitoring has become critically ill patients with the necessary care hospitals, continuous, dynamic monitoring patient's ecg activity, can send now condition changes early warning in a timely manner to give positive rescue measures, greatly improving the clinical success rate of rescue.At the same time, also reduce the workload of medical staff.If use undeserved, will provide error, lead to wrong judgment, undermine the condition observation and treatment.Therefore, the correct use of multi-function ecg monitor is very important, henan beauty medical co., LTD., introduces the following points should be paid attention to.
1. In order to strengthen the management of multi-function ecg monitor wire to avoid improper use of the medical monitoring equipment in nursing defects and mistakes some scholars reports for ecg monitoring elbow pressure sores in 1 case, the cuff is too tight for patients in a coma for beam, compression time is too long, cause local blood circulation obstacle.And researchers are reporting ecg monitor cuff pressure caused by sexual purpura in 1 case, and monitor cuff is bound for a long time, so the cuff is the correct selection and use is particularly important.Notice every time when measuring the residual gas in the cuff should be do, so as not to affect the measurement result.Continuous monitoring when do 1-2 times per shift to relax, interval 6 ~ 8 h change monitoring part 1 times.Patients with continuous use > 3 d, pay attention to on the replacement of cuff, clean and disinfect.
2. The correct use of pulse oxygen probe and wire refers to the pulse oxygen probe sensitivity, nails are too long, have any stain, dirt or loose at the end of this, a little poor blood circulation, probe, etc will affect the accuracy of monitoring data.To pay attention to when using timing observation, such as using the long, patient fingers will feel discomfort, should change another finger to guardianship, probe placed should be separated from blood pressure measuring arm.As someone special, disinfected with 75% alcohol cotton balls per class 1 times;Replacement parts once every 1 ~ 2 hours;Pay attention to take good care of the probe, properly fixed, in order to avoid collisions, fall off, damage.
3. Heart conductance united management to avoid defibrillation electrode placed parts, bone inflammation, skin redness or damaged area to the promontory, electrodes long-term application is easy to fall off, affect accuracy, general 48 ~ 72 h to replace 1 times;Pay attention to skin cleaning and disinfection.
4. Strengthen the scientific management of multi-functional monitor instrument should have special custody, fixed-point placed in instrument room, regularly check whether the equipment performance is good, all kinds of accessories are complete, the electricity, regularly find abnormal contact maintenance personnel, do a good job in succession.Equipment department technical personnel under the department

The use and maintenance of ecg monitor