亚洲国产欧洲一区二区_亚洲欧美香蕉在线日韩精选_日韩欧美日韩国产在线播放_亚洲av高清手机在线_亚洲精品无播放器播放_freevideos在线等最新內容_亚洲av无码成人h动漫_小小视频在线观看免费资源_少妇人妻系列无码专视频区_妇女满足农民工特级毛片

Wechat QR code

監(jiān)護(hù)儀廠家,腦電圖機(jī),美倫,美倫醫(yī)療電子有限公司

TEL:400-654-1200

Meilun Medical

Stock code 871562

Phone:

400-654-1200

What do you want to know?

監(jiān)護(hù)儀廠家,腦電圖機(jī),美倫,美倫醫(yī)療電子有限公司
Current position: Homepage >> News >> The latest news

Practical! Wire smart management of ECG monitor

The number of clicks:
Release date: 2018-05-07 00:00:00
Source: Henan Meilun Medical Electronics Co., Ltd.
share it

Practical! Wire smart management of ECG monitor
Ecg monitor is a basic and common monitoring means in clinic, but because there are many wires, it is easy to intertwine with each other during use and after use, and it is difficult to manage. when using the monitor, the wires between the monitor and the patient are usually long, and scattered in the bed are easily pressed under the body by the patient when the patient changes posture, which will not only cause discomfort to the patient, or pressure sores, but also delay the rescue opportunity in case of rescuing the patient.
The author introduces the following management methods through literature retrieval, hoping to help you Meilun.

Mega View M90

 

 

 

 


First, the clever use of breathing tubes
Soak the used breathing pipeline in 1000 mg / l chlorine-containing disinfectant, dry it naturally, cut off dehydrator and temperature probe adapter with a length of about 100 cm, cut it from the upper side of one end of the breathing pipeline to the other end with scissors, then wrap the wires of the ECG monitor in the breathing pipeline, and wrap the wires on the outer side in 4 sections with 2 cm wide cloth tape, which can protect the wires of the ECG monitor.
Second, the clever use of bobbin bags
The size, length and diameter of the bobbin ( PE polyethylene material ) purchased in the market depend on the number and length of the lead wires. The length of the bobbin can be cut according to the actual situation, and the bobbin can be wound on each lead wire of ECG monitoring, and then coiled around the bobbin and placed next to the monitor for later use.
Third, the use of disposable infusion sets
Take a plurality of puncture outfit for cutting off cork, Murphy's dropper, conical joint and infusion needle of disposable infusion set, take off that flow regulator, cut three or five ( three leads and five leads ) equal in length to the cardiac conductance, one equal to the extension cord of pulse oxygen, cut them from the upper side of one end of the infusion set thong to the other end with scissors, keep the edge straight, then wrap the lead wire and the extension cord of pulse oxygen around the inner side and the outer side thereof, and wrap them in a circular way with transparent adhesive tape to keep smooth and seamless to form double-layer protection for the extension cord of pulse oxygen of the lead wire.
Four, clever use of spiral plastic cable coat
Use spiral plastic cable jacket joint weaving technique to manage the lead wire. Wipe and disinfect the ECG lead wire, oxygen saturation probe wire and non-invasive blood pressure measurement wire of bedside ECG monitor, and then wrap them with black spiral plastic cable jacket from the proximal end to the distal end of the ECG monitor, and then properly fix the wrapped cable bundle on the right side of the monitor pylon, and weave the ECG lead wire in a braided hair shape from the proximal end to the distal end. pay attention to the gentle movement, and knit them to a stop at 60 cm, and then fix them with adhesive tape to prevent loosening.

Practical! Wire smart management of ECG monitor